Air Data Test Set MPS27C

RVSM Air Data Test Sets and Systems


Flightline/Ramp Air Data Test Sets
Laboratory Air Data Test Sets
Comparison Table of Air Data Test Set Features
Technical Notes on Air Data Test Set Options
Associated Products
Pitot-Static Adaptors

Portable, reliable, high accuracy, multi-output, battery powered, configurable ADTS

Flightline/Ramp Air Data Test Sets

With over 60 years experience in the design and manufacture of Air Data Test sets, DMA-Aero offer an extensive range of RVSM and Domestic RVSM (DRVSM) compliant testers. These ADTS are ideal for all work on aircraft pitot-static systems such as: leak testing; troubleshooting and full certification. With a wide range of base models and an extensive complement of options the ADTS are ideal for all pitot static air data test requirements. Precision pressure sensors are utilized, together with low power consumption which generates negligible heat, to achieve the highest accuracy available today. Offering +/- 3 feet or better at sea level, the test sets meet the stringent requirements for RVSM certification testing. The instruments are all ready for use and within the accuracy band at the conclusion of the initialization / self test procedure.

The test sets are all digitally controlled through a local or remote keypad and display. The intuitive user interface allows test set functions to be easily controlled with a minimum of key strokes, with all test parameters displayed, and is suitable for both first time and more advanced users. Optionally many of the ADTS can be remotely controlled by a PDA Pocket PC with wireless Bluetooth connection. The intelligent user interface provides protection to both the test set and the UUT. The software rejects entered command values that exceed the pre-selected limit ranges. Limits can be easily changed and are password protected for security. A pressure condition of Ps greater than Pt is prevented in both manual and automatic operation. With loss of power the test circuit is safely isolated and can be manually vented preventing instrument and test set damage.

The ADTS are applicable to all types of civil and military, fixed or rotary wing, aircraft testing. The range includes the MPS38B low cost Air Data Test Set, the MPS31C civil ADTS, the MPS27C military ADTS and the 3 channel MPS35C and MPS39C. The MPS34C offers laboratory instrument accuracy on the flight line. The latest test sets, the MPS35C and the MPS39C control three independent pressures to verify the Angle of Attack (AOA), as well as static and pitot pressures, where 'Smart' pitot tubes are used on the aircraft.

On most models internal static and pitot multiple isolators and output ports are available. Different static and pitot values can be locked into the appropriate leak free lines for checking the altitude comparator and similar functions. A new method for leak testing (one line in control mode while the other is in measure mode) ensures higher safety and avoids wasted testing time.

All the flightline/ramp Air Data Test Sets are portable and can also be used in the laboratory with either ADWIN PC software.or under control of an ATE system. They all have battery power either fitted as standard or available as an option. This allows the Air Data Test Set to be used where ac power is unavailable or for ADTS operation to continue during power failure. All the test sets are engineered to minimize power consumption which extends battery life.

All models have internal pumps which run 'on demand' to reach maximum life duration associated with low electrical power consumption. Noise level is very low, a welcome feature when the ADTS is used in the workshop. Most models contain DMA's specially engineered high reliability 5,000 hour warranted pump.

On all ADTS, 30 User test profiles are programmable and executable, each with 26 test points, ideal for FAR43/FAR91 testing. Some models are fitted with a Compact Flash memory card for storing results. Calibration adjustments are made by software input only with no hardware adjustment required. A comprehensive list of options is available with some models being pre-configured for certain options. Amongst the available options are:

  • 28 VDC operation
  • IEEE488 control (RS232 control is standard on most models)
  • ARINC429 interface
  • PDA for bluetooth control
  • Multiple isolated static and pitot outputs controlled from the keypad
  • ADWIN software for PC control
  • Hand held remote control unit
  • Encoding altimeter readout
  • Military ranges of 850 or 1,000 kts
  • Internal battery
  • External battery to extend battery life
  • External pressure and vacuum supply

Please inquire on any other option requirements such as radio altimeter automatic test.

A large range of pitot-static adaptors can be supplied.

Laboratory Air Data Test Sets

DMA is a leading manufacturer of ADTS models for laboratory RVSM and DRVSM compliant air data/pitot-static testing with the highest accuracy and resolution. The MPS36 Air Data Test Set uses the most accurate pressure sensors currently available, with a special characterization for maximum accuracy ( ±2 feet at sea level for static channel). Pressure resolution of 0.2 Pa.is also achievable. It is digitally controlled through a user keyboard and the human interface ensures that all the functions are controlled with a minimum of key presses. The ADTS can also be used in avionics ATE systems via RS232 and/or GPIB/IEEE488 or controlled from a PC with ADWIN control software. An internal or external rack mounted pump unit can be supplied as an option. Many of the functions and option capabilities are in common with the flight line air data test systems.

Air Data Test Set Features

Type No
MPS27C
MPS30
MPS30BW
MPS31C
MPS34C
MPS35C
MPS36
MPS38B
MPS39C
Picture
Click to enlarge
Click to see larger picture of Air Data Test Set MPS27C
Click to see larger picture of Air Data Test Set MPS30
Click to see larger picture of Air Data Test Set MPS30BW
MPS31C Air Data Test Set larger picture
Click to see larger picture of Air Data Test Set MPS34C
Click to see larger picture of Air Data Test Set MPS35C
Click to see larger picture of Air Data Test Set MPS36
Click to see larger picture of Air Data Test Set MPS38
Click to see larger picture of Air Data Test Set MPS35C
Data sheet
Click to download
Click to open MPS27C Air Data Test Set data sheet
Click to open MPS30 Air Data Test Set data sheet
See MPS30
Click to open MPS31C Air Data Test Set data sheet
Click to open MPS34C Air Data Test Set data sheet
Click to open MPS35C Air Data Test Set data sheet
Click to open MPS36 Air Data Test Set data sheet
Click to open MPS38 Air Data Test Set data sheet
Click to open MPS39C Air Data Test Set data sheet
Accuracy
Hi
Hi
Hi
Hi
Very Hi
Hi
Very Hi
Hi
Hi
Case
flightline
flightline
flightline
flightline
flightline
flightline
Rack
flightline
flightline
Size
large
large
large
medium
large
large
3U high
small
large
Range Alt
max
max
max
medium
max
max
max
medium
max
Large Pump
yes x 1
2 as option
yes x 2
yes x 2
yes x1
yes x 2
yes x 2
n/a
no
yes
Keyboard
yes
no
no
yes
yes
yes
yes
yes
yes
Hand Terminal
Option
yes
yes
Option
yes
Option
Option
no
yes
Flash Card
yes
no
no
no
yes
yes
no
no
no
Battery
yes-4hr
Option
Option
yes-2hr
yes-4hr
yes-4hr
no
no - an external option available
yes-4hr
4+4 Isolate
Option
Option
yes
Option
yes
yes
Inquire
no
Option
3+3 Isolate
Option
Option
no
Option
no
no
no
no
no
2+2 Isolate
Option
Option
no
Option
no
no
no
no
no
Bluetooth Remote
Tx/Rx std.
PDA Option
Tx/Rx std.
PDA Option
no
Tx/Rx std.
PDA Option
Tx/Rx std.
PDA Option
Tx/Rx std.
PDA Option
Tx/Rx std.
PDA Option
no
Tx/Rx std.
PDA Option
Alt. Encoder
Option
Option
yes
Option
yes
Option
Option
no
Option
AoA Channel
no
no
no
no
no
yes
no
no
yes
GPIB
Option
Option
Option
Option
Option
Option
Option
no
Option
28V DC
Option
Option
Option
Option
 
Option
Option
no
no-use EPU8E
Option
ARINC
Option
Option
Option
Option
Option
Option
Option
no
Option

Click image to see enlargement of Hand Terminal Click to enlarge image of Air Data Test Set Hand Terminal and Bluetooth Remote Control Click to enlarge image of bluetooth remote control PDA for use with Air Data Test Systems

Technical Notes

The following technical notes provide further information on product options (PDF documents).


Pitot-Static Adaptor Kits
ADWIN Software for PC control of an Air Data Test Set
Bluetooth control of ADTS from a PDA or PC
ARINC 429 and MIL-STD-1553 interface buses for the MPS range
Multi-port switching option
Rack mounted Pressure and Vacuum supply unit
Radio Altimeter Ground Proximity Warning Computer testing

Associated Products

The EPU8E extends battery life to 8 hours

Type
EPU8E
Picture
Click to enlarge
External battery in flight case

Data Sheet
Click to download

External battery pack to extend battery life

Pressure and vacuum supply unit for MPS36

Type
EPS1
Picture
Click to enlarge
External pressure and vacuum supply

Data Sheet
Click to download

external pressure and vacuum supply data sheet

Pitot-static adaptors

A large variety of pitot-static adaptors can be supplied to interface Air Data Test Sets to aircraft and helicopters. The adaptors are supplied in a rugged waterproof case, complete with PVC pipes, red warning flags, pneumatic connections to ADTS, and in some instances with suction fixing pipe stands to aircraft static ports. A color code allows the identification of the static or pitot ports connected, this feature is useful when using the Multiple Isolator Option available on our ADTS. Adaptors have a special design to safeguard the aircraft pitot static ports, which could be damaged if poor quality fixing devices are used.

Type
Pitot-static adaptors
Picture
Click to enlarge
Pitot-static adaptor kit

Data Sheet
Click to download

Pitot-static adaptor kit data sheet


Air Data Test Sets | Pressure Indicators | Pressure Controllers | Tachometer Testers | Thermal Sensor Testers | Tilt Tables | Angular Protractors

Top | Home | Company | Markets | Technology | Events | Products | Support | Contact | Terms of use | Site map
© DMA-Aero 2006